Motor Connecting Cables
2YSLCY-JB/2YSLCYK-JB 9YSLCY-JB PENDANT CABLE  

Mineral insulated cables

Fluoropolymer-insulated Heating Cable up to 260 °C

Application

Vessels, piping, valves

Small components

Industrial areas

Rotor blades

Marble plates

Standard

DIN VDE 0253

Voltage Rating

750V

CABLE CONSTRUCTION

Heating conductor.

Insulation: Fluoropolymer.

Mechanical and Thermal Properties

Maximum operating temperature: 260℃

Minimum installation temperature: -60℃

Minimum bending radius: 2.5xOD

Maximum output: 30 W/m

Nominal resistance of heating conductor: 8000 Ω/km

Cable Parameter

Nominal resistance
Ω/km

APPROX.
outer diameter mm

7APPROX.
weight g/m

Temperature coefficient
x 10¯³/K

1.95

5.8

112

4.3

2.90

4.6

73

4.3

4.40

4.2

54

4.3

7.20

3.1

33

4.3

10.0

3.0

31

4.3

11.7

2.7

30

4.3

15.0

2.6

19

4.3

25.0

2.5

17

3.0

31.5

2.9

23

1.6

50.0

2.6

17

1.6

65.0

2.4

14

0.9

80.0

2.7

20

0.9

100.0

2.5

17

0.45

157.0

2.5

17

0.45

180.0

2.2

12

0.90

200.0

2.4

14

0.45

260.0

2.2

12

0.45

280.0

2.1

10

0.38

328.0

2.5

16

0.18

360.0

2.1

10

0.45

430.0

2.3

13

0.18

480.0

2.2

12

0.18

600.0

2.1

10

0.18

800.0

2.0

9

0.18

1000.0

2.1

10

0.04

1470.0

2.1

9

0.04

1750.0

2.0

8

0.04

1900.0

2.2

12

0.04

2900.0

2.1

9

0.04

4000.0

2.0

8

0.04

4700.0

1.9

8

0.15

6000.0

1.9

7

0.20

7000.0

2.0

7

0.15

8000.0

2.0

7

0.15